Label #2
Label #3
Label #4
Special Notes 1. If Vertical and Horizontal position is not specified in the command,
all data preceding the command will be mirrored.
2. This command can be used with the <ESC>% Rotate Fixed Base
Reference Point command (see Page 4-68). It cannot be used
with the <ESC>R Rotate Moving Base Reference Point command
(see Page 5-68). Please note that the reference point rotation is
dependent upon the location of the <ESC>% command in the
data stream
3. This command should not be specified more than once in any
single job.
4. This command cannot be used with commands requiring re-editing
of the print area, such as Sequential Numbering, Real time clock
or Copy Image Area.
5. Any data outside the printable area is not mirrored the command is
treated as a command error. Any print job containing the
<ESC>RM comand and without any print data will be treated as a
command error.