5. Use the cotton swab to clean any foreign matter from the exposed surface of the
sensors.
REPLACING THE FUSE CL608e and CL612e
Supplies needed: 250V 3A Fuse
1. Turn the printer power off and remove the power cable.
2. On the back of the printer, locate the Fuse Cap directly above the AC connector.
3. Unscrew the cap and remove the defective fuse.
4. Replace with a new 250V 3A fuse.
5. Screw the cap back onto the printer and replace the power cord.
Page 4-6 9001074 Rev. B SATO CL Series “e” Printers